{"id":2866,"date":"2021-08-19T15:54:03","date_gmt":"2021-08-19T19:54:03","guid":{"rendered":"https:\/\/www.albrechtengineering.com\/?page_id=2866"},"modified":"2021-08-20T09:38:00","modified_gmt":"2021-08-20T13:38:00","slug":"cedar-lane-pumping-station","status":"publish","type":"page","link":"https:\/\/www.albrechtengineering.com\/index.php\/cedar-lane-pumping-station\/","title":{"rendered":"Cedar Lane Pumping Station"},"content":{"rendered":"<p><strong>Project Status:<\/strong><br \/>\nComplete<br \/>\n<strong>Budget: <\/strong><br \/>\n$4,685,000<br \/>\n<strong>Address: <\/strong><br \/>\n6040 Cedar Lane (corner of Hilltop Rd.)<br \/>\nColumbia, MD 21044<\/p>\n<p>Provided structural engineering services for a new, concrete framed water pumping station. The station is approximately 4,500 sf and has a capacity of 4 MGD. The station provides a backup water supply to increase reliability in the 630 West pressure zone.<\/p>\n<div class='yrm-content yrm-content-1 yrm-content-hide' id='yrm-2gAwz' data-id='1' data-show-status='false' data-after-action='' style=\"visibility: hidden;height: 0;\">\n\t\t\t<div id='yrm-inner-content-yrm-2gAwz' class='yrm-inner-content-wrapper yrm-cntent-1'><\/p>\n<p>The scope of work included structural engineering for a single story pumping station with a lower level basement. Responsible for the design of all structural elements, which included: concrete basement walls, base slab, elevated framing, crane support columns, masonry walls, precast concrete ceiling, and development of loading diagrams for a light-gage metal truss roof.<\/p>\n<p>Performed structural calculations. Determined the live and dead gravity loads, and wind, seismic, and lateral loads below grade. Performed calculations utilizing TEDDS and Staad Pro. Prepared plans and details using REVIT.<\/p>\n<p>Performed Construction Administration Services including review of submissions, change orders and RFIs. Prepared as-built plans.<\/p>\n<p><\/div>\n\t\t<\/div><div class='yrm-btn-wrapper yrm-btn-wrapper-1 yrm-more-button-wrapper  '\n\t\tdata-custom-more-class-name='' data-custom-less-class-name=''><span title='' data-less-title='' data-more-title='' class='yrm-toggle-expand  yrm-toggle-expand-1 ' data-rel='yrm-2gAwz' data-more='Read More' data-less='Read Less'><span class='yrm-text-wrapper yrm-text-wrapper-custom-dimensions'><span class=\"yrm-button-text-1 yrm-button-text-span\">Read More<\/span><\/span><\/span><\/div>\n<p><!--<a href=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPS.jpeg\"><img loading=\"lazy\" src=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPS.jpeg\" alt=\"CLPS\" width=\"1200\" height=\"1650\" class=\"alignleft size-full wp-image-2871\"><\/a>--><\/p>\n<style>.eic-frame-2878 { width: 1207px; height:1149px; background-color: #ffffff; border: 7px solid #ffffff; }.eic-frame-2878 .eic-image { border: 7px solid #ffffff; }<\/style><div class=\"eic-container\"><div class=\"eic-frame eic-frame-2878 eic-frame-2-row-top-2-col\" data-layout-name=\"2-row-top-2-col\" data-orig-width=\"1207\" data-orig-border=\"7\" data-ratio=\"1.05\"><div class=\"eic-rows\"><div class=\"eic-row eic-child-1\" style=\"top: 0; left: 0; right: 0; bottom: 50%; height: 50%;\"><div class=\"eic-cols\"><div class=\"eic-col eic-child-1\" style=\"top: 0; bottom: 0; left: 0; right: 50%; width: 50%;\"><div class=\"eic-image eic-image-0\" data-size-x=\"810\" data-size-y=\"554\" data-pos-x=\"-109\" data-pos-y=\"0\"><img src=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPSC1.jpg\" style=\"width: 810px !important;height: 554px !important;max-width: none !important;max-height: none !important;position: absolute !important;left: -109px !important;top: 0px !important;padding: 0 !important;margin: 0 !important;border: none !important;\" title=\"Interior\" alt=\"Interior\" \/><a href=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPSC1.jpg\" rel=\"lightbox\" title=\"Interior\" class=\"eic-image-link \" target=\"_blank\"><\/a><\/div><\/div><div class=\"eic-col eic-child-2\" style=\"top: 0; bottom: 0; right: 0; left: 50%; width: 50%;\"><div class=\"eic-image eic-image-1\" data-size-x=\"583\" data-size-y=\"1025\" data-pos-x=\"0\" data-pos-y=\"-136\"><img src=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPSC2.jpg\" style=\"width: 583px !important;height: 1025px !important;max-width: none !important;max-height: none !important;position: absolute !important;left: 0px !important;top: -136px !important;padding: 0 !important;margin: 0 !important;border: none !important;\" title=\"Structural Detailing\" alt=\"Structural Detailing\" \/><a href=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPSC2.jpg\" rel=\"lightbox\" title=\"Structural Detailing\" class=\"eic-image-link \" target=\"_blank\"><\/a><\/div><\/div><\/div><\/div><div class=\"eic-row eic-child-2\" style=\"bottom: 0; left: 0; right: 0; top: 50%; height: 50%;\"><div class=\"eic-image eic-image-2\" data-size-x=\"1232\" data-size-y=\"554\" data-pos-x=\"-4\" data-pos-y=\"0\"><img src=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPSC3.jpg\" style=\"width: 1232px !important;height: 554px !important;max-width: none !important;max-height: none !important;position: absolute !important;left: -4px !important;top: 0px !important;padding: 0 !important;margin: 0 !important;border: none !important;\" title=\"Exterior\" alt=\"Exterior\" \/><a href=\"https:\/\/www.albrechtengineering.com\/wp-content\/uploads\/2021\/08\/CLPSC3.jpg\" rel=\"lightbox\" title=\"Exterior\" class=\"eic-image-link \" target=\"_blank\"><\/a><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Project Status: Complete Budget: $4,685,000 Address: 6040 Cedar Lane (corner of Hilltop Rd.) Columbia, MD 21044 Provided structural engineering services for a new, concrete framed water pumping station. The station is approximately 4,500 sf and has a capacity of 4 MGD. The station provides a backup water supply to increase reliability in the 630 West [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/pages\/2866"}],"collection":[{"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/comments?post=2866"}],"version-history":[{"count":7,"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/pages\/2866\/revisions"}],"predecessor-version":[{"id":2884,"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/pages\/2866\/revisions\/2884"}],"wp:attachment":[{"href":"https:\/\/www.albrechtengineering.com\/index.php\/wp-json\/wp\/v2\/media?parent=2866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}